Fortinet udostępnił aktualizację oprogramowania dla FortiSwitch o oznaczeniu wersji 7.0.6. Nowością w tej wersji oprogramowania jest wsparcie dla atrybutów RADIUS podczas żądań płynących z mechanizmu CoA (Change of Authorization). Aktualizacja przynosi również rozwiązanie kilku problemów zgłaszanych przez administratorów – więcej w artykule poniżej.
Co nowego w FortiSwitch 7.0.6:
Release 7.0.6 provides the following new features:
- Three RADIUS attributes are now supported for RADIUS CoA-Request messages:
- Tunnel-Type—VLAN (13)
- Tunnel-Medium-Type—IEEE-802 (6)
- Tunnel-Private-Group-ID—VLAN ID or VLAN name (13)
NOTE: These attributes are also supported in FortiSwitchOS 6.4.12 and 7.2.2 or later.
- The default value for the
set dhcp-snoop-client-req
command (underconfig system global
) is nowdrop-untrusted
, instead offorward-untrusted
.
Aktualnie wspierane modele:
FortiSwitch 1xx | FS-108E, FS-108E-POE, FS-108E-FPOE, FS-108F, FS-108F-POE, FS-108F-FPOE, FS-124E, FS-124E-POE, FS-124E-FPOE, FS-124F, FS-124F-POE, FS-124F-FPOE, FS-148E, FS-148E-POE, FS-148F, FS-148F-POE, FS-148F-FPOE |
FortiSwitch 2xx | FS-224D-FPOE, FS-224E, FS-224E-POE, FS-248D, FS-248E-POE, FS-248E-FPOE |
FortiSwitch 4xx | FS-424D, FS-424D-FPOE, FS-424D-POE, FS-424E, FS-424E-POE, FS-424E-FPOE, FS-424E-Fiber, FS-M426E-FPOE, FS-448D, FS-448D-FPOE, FS-448D-POE, FS-448E, FS-448E-POE, FS-448E-FPOE |
FortiSwitch 5xx | FS-524D-FPOE, FS-524D, FS-548D, FS-548D-FPOE |
FortiSwitch 1xxx | FS-1024D, FS-1024E, FS-1048D, FS-1048E, FS-T1024E |
FortiSwitch 3xxx | FS-3032D, FS-3032E |
FortiSwitch Rugged | FSR-112D-POE, FSR-124D |
Rozwiązane problemy:
Bug ID | Description |
---|---|
801678 | After enabling MAC authentication bypass (MAB) on some FortiSwitch models, the FortiGate device removes the NAC device after an inactivity timeout. |
806907 | Packet loss occurs when using the SP-CABLE-FS-SFP+5 direct-attach cable with FS-124F switches. |
824605 | The object identifier (OID) 1.3.6.1.2.1.10.7.2.1.19 does not work on FS-1048E. |
831495 | The TV multicast receivers do not unsubscribe from the multicast stream. |
831546 | Logging in to a FortiSwitch unit that is managed by FortiSwitch Manager displays a message that incorrectly refers to FortiLink and FortiGate. |
837168 | The following switches make a high fan noise:
|
846994 | Configuring the set group-name command under config match for config user tacacs+ does not work. |
848619 | After configuring the set speed auto-module command (under config switch physical-port ) on some switches (such as the FS-124F or FS-148F), the fiber interface does not come up. |
849465 | Using FN-TRAN-GC with the FS-108E or FS-108F switch causes link flapping or wrongly shows that the link is up when the cable is not connected. |
850859 | FortiSwitchOS sends the wrong OID for the SNMPv3 trap for link-down events. |
857391 | After upgrading FortiSwitchOS, some switch models report that the fan has failed, although the fan status is OK. |
858223 | The “System reboot is required after disk error” log entry is incorrectly labeled as “notice,” instead of “emergency.” |
861492 | The mgmt interface MAC address is set to 00:01:02:03:04:05 after a reboot or factory reset. |
866231 | The set status down command (under config switch physical-port ) does not work on the SFP+ ports on the FS-426E-FPOE for certain versions of FortiSwitchOS. If you need to shut down any of the SFP+ ports on the FS-426E-FPOE, do not use FortiSwitchOS 7.0.5, 7.2.0, 7.2.1, or 7.2.2. |
867758 | FortiSwitch units using IPv6 do not respond to SNMPv3 requests. |
869616 | The FortiAnalyzer and FortiSwitch logs have multiple entries about the fan tray being detected or undetected on an FS-1048E switch, although the fan status is good. |
Znane problemy:
Bug ID | Description |
---|---|
382518, 417024, 417073, 417099, 438441 | DHCP snooping and dynamic ARP inspection (DAI) do not work with private VLANs (PVLANs). |
414972 | IGMP snooping might not work correctly when used with 802.1x Dynamic VLAN functionality. |
463161 | Upgrading the FS-448D from FortiSwitchOS 3.5.6 to 3.6.3 fails with an “Invalid root configuration data.” error. |
480605 | When DHCP snooping is enabled on the FSR-112D-POE, the switched virtual interface (SVI) cannot get the IP address from the DHCP server.
Workarounds: |
510943 | The time-domain reflectometer (TDR) function (cable diagnostics feature) reports unexpected values.
Workaround: When using the cable diagnostics feature on a port (with the |
542031 | For the 5xx switches, the diagnose switch physical-ports led-flash command flashes only the SFP port LEDs, instead of all the port LEDs. |
548783 | Some models support setting the mirror destination to “internal.” This is intended only for debugging purposes and might prevent critical protocols from operating on ports being used as mirror sources. |
572052 | Backup files from FortiSwitchOS 3.x that have 16-character-long passwords fail when restored on FortiSwitchOS 6.x. In FortiSwitchOS 6.x, file backups fail with passwords longer than 15 characters.
Workaround: Use passwords with a maximum of 15 characters for FortiSwitchOS 3.x and 6.x. |
585550 | When packet sampling is enabled on an interface, packets that should be dropped by uRPF will be forwarded. |
606044, 610149 | The results are inaccurate when running cable diagnostics on the FS-108E, FS-124E, FS-108E-POE, FS-108E-FPOE, FS-124E-POE, FS-124E-FPOE, FS-148E, and FS-148E-POE models. |
609375 | The FortiSwitchOS supports four priority levels (critical, high, medium, and low); however, The SNMP Power Ethernet MIB only supports three levels. To support the MIB, a power priority of medium is returned as low for the PoE MIB. |
667079 | For the FSR-112D-POE model:
|
673433 | Some 7-meter DAC cables cause traffic loss for the FS-448E model. |
724813 | The set enforce-first-as {disable | enable} command should have been placed under config neighbor and does not work in its current location (directly under config router bgp ). There is no patch available for this issue. |
784585 | When a dynamic LACP trunk has formed between switches in an MRP ring, the MRP ring cannot be closed. Deleting the dynamic LACP trunk does not fix this issue. MRP supports only physical ports and static trunks; MRP does not support dynamic LACP trunks.
Workaround: Disable MRP and then re-enable MRP. |
833450 | Do not use multicast IP addresses in the ranges of 224-239.0.0.x and 224-239.128.0.x on the FS-2xxD, FS-2xxE, FS-4xxD, and FS-4xxE models. |
Notatki producenta: FortiSwitch 7.0.6